Check steps
1. The Automatic Vacuum loader feeding system can first check whether there are any problems on the touch screen of the control system. For example, the various parameters of the vacuum suction machine, the time of suction and discharge are all right, if there is a problem here, the suction machine will have The material may not feeding normally, and it should Timely processing
2. Check the pneumatic pump of the equipment to see if its compressed air source pressure meets the relevant regulations. In most cases, the air source pressure of the pneumatic pump is between 6 and 7mpa. If the pressure does not meet the relevant requirements, you should check whether the air source needs to use with the ventilation pipe.
3. The Automatic Vacuum loader cannot perform suction normally because of the disassembly and assembly activities of the machine. The upper cover and the cylinder clamp show air leakage, and the suction operation cannot running normally.
4. Open the upper cover of the feeder, take out the filter plate and investigate whether there is too much dust on the filter element, or there may be agglomeration, this kind of problem may make the suction machine unable to If the material is sucked normally, this problem occurs, as long as it is blown clean with compressed air.
5. Check the suction pipe to see if there is an air leak on it, and other attention should be paid to whether there are sealing rings on all the clamps.
If you still can’t find the reason, you can find the relevant professional personnel to check it. .
About US
ProWell Tech is a R&D and manufacturer of auxiliary equipment for automatic feeding systems. The company has complete domestic technology in material transportation, mixing, weighing, vacuum metering, dehumidification, filling, etc. We can provide customers in different industries with central feeding installation design solutions. Welcome to inquire.